By the SightShield team · · 3 min read
Cabling is the part of the network you keep the longest
Laptops change every three or four years, switches and access points every five to seven. The cables in the walls and ceilings are expected to serve for 15 years or more. Structured cabling is the practice of installing that cabling as an organised, standards-based system rather than a tangle of cables run as each need arises.
The parts of a structured cabling system
- Entrance facility: where the ISP’s fibre or copper enters the building.
- Equipment room or network rack: holds the router, firewall, switches, NVR and patch panels.
- Backbone cabling: links between racks on different floors or buildings — usually fibre, sometimes Cat6A.
- Horizontal cabling: the permanent run from the rack to each outlet, access point, camera or device.
- Patch panels: where horizontal cables terminate in the rack, so equipment is connected with short patch cords.
- Outlets: the wall, floor or ceiling points that devices plug into.
The 100-metre rule
Copper Ethernet (Cat5e, Cat6 and Cat6A) is designed for a channel of up to 100 metres: up to 90 metres of permanent cable from patch panel to outlet, plus up to 10 metres of patch cords at both ends. Longer runs may appear to work but drop speed or cause intermittent faults. For longer distances, add a switch closer to the devices or use fibre.
What “structured” looks like in practice
- Every cable terminates on a patch panel or keystone outlet — never directly into a switch.
- Each cable has a matching label at both ends, such as “2F-14”, recorded in a port schedule.
- Cables run in trays, conduits or trunking, kept away from power cables and bent no tighter than the manufacturer allows.
- Patch cords are short, colour-coded by use (for example, blue for data, red for CCTV, yellow for Wi-Fi) and dressed with cable managers.
- Spare capacity: a few extra cables to busy areas and space in the rack for growth.
Testing and certification
Every run should be tested after termination. A basic tester confirms that all eight wires are connected correctly. A certification tester goes further, measuring length, loss and crosstalk against the category standard and producing a report — the proof that a Cat6 link actually performs as Cat6. Ask for test results as part of the handover, especially in offices.
New Office IT Setup Checklist →Example: a 40-person office fit-out
For a 40-person office in HSR Layout, the cabling plan included two network points per desk, points for six ceiling access points, eight CCTV cameras, two attendance terminals, the reception phone and printers — about 110 Cat6 runs in total. All runs ended on patch panels in a 27U rack beside the server room door, with cable managers, a labelled patch panel and a UPS. Every point was tested and the results handed over with a floor plan showing point numbers. Two years later, when the company added a meeting room and four cameras, spare points and labelled panels made the change a one-day job.
Network racks explained →Why it pays off
With structured cabling, moving a desk, adding an access point or tracing a fault is a five-minute patch change instead of a new cable run. It also means CCTV, Wi-Fi, biometric machines, IP phones and computers can share one tidy infrastructure while staying on separate networks. For new buildings, it is far cheaper to lay cabling during construction — before false ceilings and plaster — than to retrofit it.
See our IT infrastructure service →Quick answers
Is structured cabling only for large offices?+
No. The same principles — a small rack, a patch panel and labelled runs — make a villa or a 10-person office far easier to maintain.
Can CCTV and computers share the same cabling?+
Yes. They share the cabling and rack but sit on separate VLANs so each system is isolated.
How long does structured cabling last?+
Well-installed Cat6 or Cat6A cabling is commonly expected to serve 15 years or more, across several generations of equipment.
Do you provide a cabling report?+
Yes. We label every point and hand over a port schedule and test results.
How many network points should each desk have?+
Two is a common standard: one for the computer or dock and one spare for a phone or future device.
Should CCTV and office points share the rack?+
They can share the rack and patch panels, but should be on a separate VLAN or switch for security.